Introduction

Principle & Structure

Using the heat transfer temperature difference technology, the heating module and the infection module are placed in the closed probe. The heat conduction of the probe is closely related to the flow rate of the measured medium. When the medium in the pipeline flows at a stable flow rate, the sensing module receives the heating module. is a fixed value. When the flow rate flowing through the probe changes, the thermal module will send out the corresponding temperature difference signal, and the processor will output the result corresponding to the flow rate.

Features

No moving parts, maintenance-free, easy to install, one model is suitable for a variety of pipe diameter requirements. The switching value is continuously adjustable, extremely low pressure loss, 6 LEDs, etc. In addition to displaying the switching point action, it also has a flow trend display function . There are various output functions to choose from. Meet the needs of different users for automation control.

application

Hydraulic dual-purpose type, can be used in pneumatic and hydraulic systems, and can be used for interrupted flow monitoring of circulating water, cutting fluid and lubricating oil, as well as idling protection of pumps.

technical parameter

Predetermined area:3…300cm/s (water), 3…300cm/s (oil), 200…3000cm/s (air)Switching Accuracy:±1~±10cm/s
Signal output:PNP, NPN, relay (transistor output needs 24V power supply); normally open + normally closed (SPDT)load:5A (relay type)
Probe length:15mm\20mm\30mm\special customization according to customer requirementspower:5w
No-load current:250mA maxCurrent consumption:<60mA
Flow indication:LED row (6 pcs)Setting method:Potentiometer setting
Pressure range:100barMedium temperature change:≤4℃/s
Response time:1–10s, typical 2sInitialization time:about 8s
Electrical Protection:Inverted, short circuit, overload protectionProtection class:IP67
Medium temperature:-20~80℃Ambient temperature:-20~80℃
Storage temperature:-20~100℃Wiring:M12*1 connector
Material:Probe: 316L Stainless Steel; Housing: 316L Stainless Steelweight:About 0.4kg

Selection table

FS62-Universal Flow Monitor

Thread details

Interface thread G1/2

Interface thread G1/4

Connection method

External thread of interface thread

Power supply

DC power distribution 24V±20%DC

AC 110VAC power supply (need to note high and low alarm points)

AC 220VAC power supply (need to note high and low alarm points)

output signal

PNP transistor output (optional when supplying DC24V)

NPN transistor output (optional when supplying DC24V)

relay output

Probe length (without thread)

Probe length: 15mm

Probe length: 20mm

Probe length: 30mm

Customized according to customer requirements (for example, the 40mm option is marked as "N40")
The complete data of this selection table, please contact the sales staff or email to sales@kewill-auto.cn for complete samples.
Prev :FS61 Series Basic Flow Monitor
Next:FS63 Series Digital Flow Monitor