Introduction

Principle & Structure

Using the heat transfer temperature difference technology, the heating module and the infection module are placed in the closed probe. The heat conduction of the probe is closely related to the flow rate of the measured medium. When the medium in the pipeline flows at a stable flow rate, the induction module receives the temperature sensed by the heating module. is a fixed value. When the flow rate flowing through the probe changes, the thermal module will send out the corresponding temperature difference signal, and the processor will output the result corresponding to the flow rate.

Features

No moving parts, maintenance-free, easy to install, one model is suitable for a variety of pipe diameter requirements. The switching value is continuously adjustable, extremely low pressure loss, ultra-clear LED digital display flow percentage, and a variety of output functions to choose from. Meet the needs of different users for automation control.

application

The gas-liquid dual-purpose type can be used in pneumatic and hydraulic systems, and can be used for the interruption monitoring of circulating water, cutting fluid and lubricating oil, as well as the idling protection of the pump.

technical parameter

Predetermined area:3…300cm/s (water), 3…300cm/s (oil), 200…3000cm/s (air)Switching Accuracy:±1~±10cm/s
Signal output:PNP, NPN, relay, two-way relay. Analog (4…20mA)load:5A (relay type)
No-load current:250mA maxCurrent consumption:<60mA
powered by:24VDC 、110VAC 、220VACSetting method:Two button setting
Flow Indication::LED clear digital displayMedium temperature change:≤4℃/s
Response time:1–10s, typical 2sInitialization time:about 8s
Electrical Protection:Inverted, short circuit, overload protectionProtection class:IP67
Medium temperature:-20~80℃Ambient temperature:-20~80℃
Storage temperature:-20~100℃Wiring:M12*1 connector
Material:Probe: 316L Stainless Steel; Housing: 316L Stainless Steelweight:About 0.4kg
Probe length:15mm\20mm\30mm\special customization according to customer requirementsPressure range:100bar

Selection table

FS63-Digital flow monitor

Thread details

Interface thread: external thread G1/2

Interface thread: external thread G1/4

Interface thread: Internal thread M18*1.5

Connection method

External thread of interface thread

Internal thread of interface thread

Power supply

DC power distribution 24V±20% power supply

AC 110VAC power supply (need to note high and low alarm points)

AC 220VAC power supply (need to note high and low alarm points)

output signal

PNP transistor output (optional when supplying DC24V)

NPN transistor output (optional when supplying DC24V)

Relay output (Relay)

4…20mA current signal output

4…20mA output + relay output

Two relay outputs (Relay*2)

4…20mA output + two relay outputs (Relay*2)

Probe length (without thread)

Probe length: 15mm

Probe length: 20mm

Customized according to customer requirements (for example, the 40mm option is marked as "N40")
The complete data of this selection table, please contact the sales staff or email to sales@kewill-auto.cn for complete samples.