Introduction

Product Description

TK80T is a hygienic temperature transmitter specially designed for food hygiene, medicine and environmental protection. The product design conforms to FDA\GMP standards. Use PT100 or PT1000 thermal resistance for temperature measurement, and the signal is converted into standard industrial electrical signal output after being processed by the circuit. The whole 1.4435 stainless steel shell is designed so that it will not pollute the measuring medium and the environment, and the special food hygiene-grade process connection can ensure that there is no dead angle for disinfection.

main feature

The finish and material meet the general requirements of food hygiene

The material meets the general requirements of food hygiene

Special food hygiene clamp connection

Measuring range -50…200 degrees

Can be integrated with multi-style on-site display instruments to realize multi-point switch control

technical parameter

Temperature and Accuracy
Range :-50...200 
Ambient temperature:30 ℃ ...100 
storage temperature:-30 ℃ ...140 
Relative humidity:0...80%
Control accuracy :±0.25%FS
Display accuracy :±0.15FS
Display mode :No local/remote transmission can cooperate with display
sensor:PT1000 Class A
PT100 Class A


Material pressure protection
Pressure resistance :40bar
Protection class:IP67
Shell :Stainless steel 1.4301 304 )
Media contact part:Stainless steel 1.4435 (316L)


Output power supply and wiring
Power Range:DC  10...30Vdc
Current signal:-wire 4...20mA RA ≤ ( Us-10)V/0.02A
Maximum power consumption:3W
Lead way:M12*1 Aviation Plug

Internal thread G1/2  explosion-proof interface

Selection table

TK80T-Sanitary Temperature Transmitter

output output type

Analog 4...20mA current output
Analog 1...5V voltage output
Probe Diameter (D)

Φ6 can withstand pressure of 40 bar (length L≤1000mm optional) (*)
Φ8 can withstand pressure 40 bar
Clamp connection

DN20 sanitary clamp diameter 50.5mm
DN25 sanitary clamp diameter 50.5mm (*)
DN40 sanitary clamp diameter 50.5mm
DN50 sanitary clamp diameter 64mm
DN60 sanitary clamp diameter 77.5mm
DN80 sanitary clamp diameter 91mm
DN100 sanitary clamp diameter 119mm
Probe length (L)

15mm(*)
25mm
50mm(*)
75mm
100mm(*)
Customized
Way out

M12*1 aviation patch cord
G1/2 explosion-proof interface
temperature range
XFor details, please refer to "Regular Range Code Table"

Accuracy class
A±0.2%
B±0.5%
This PDF does not contain the complete data of the selection table. For selection, please contact the sales staff or email to sales@kewill-auto.cn to obtain the complete sample.
Remarks: "*" is marked as stock standing or fast delivery
Prev :TK80 Series Hygienic Temperature Sensor
Next:No