Introduction
principle
When the main part of the float ball rises or falls towards the liquid level, it drives the stainless steel magnetic float ball to move up and down. When the angle of the lift line is greater than or equal to 28°, the steel ball inside the trigger switch will roll and press to the point of fretting. Switch or disengage the fretting. Use the micro switch as the contact output to output the contact signal of the liquid level switch ON or OFF.
Features
● Simple structure and reliable performance
● Easy to install and can be debugged on site, suitable for measurement of water supply and drainage, corrosion and suspended solids conditions
● On-site suspension installation, which is suitable for use in underground pools
● All parts in contact with liquid are made of plastic (stainless steel) with good corrosion resistance
● Can be used for limit monitoring or continuous monitoring of liquid level. Switch value type can provide multi-ball multi-point monitoring.
application
Gas-liquid dual-use, industrial automation / mechanical equipment / air compression industry / refrigeration and air conditioning.