Introduction

Principle & Structure

Hydrostatic level transmitter, the best choice for OEM customers.

Features

Wide operating temperature range, compact structure, suitable for harsh environments, high reliability. Wide range (0~600bar), can be used to measure gauge pressure and absolute pressure.

technical parameter

Measuring range:0~0.5m to 50mAccuracy:0.2%Storage temperature:-30~100℃
Linearity:±0.2%Repeatability:≤±0.1FSProtection class:IP65
stability:Better than 0.01% of span per yearTemperature effect:<±0.02%FS/Kshell material:Stainless steel 1.43.1 (304)
Response time:<1ms(10…90%FS)powered by:10~30V DCWetted material:Stainless steel 1.4435 (316L)
load:≥10KΩ(0..10V),≥5KΩenergy consumption:Signal current (2-wire), 8mA (3-wire)seal:Fluorine rubber O-ring
≤(UB-10)V/ 0.02A (4~20mA)
Electrical Protection:Overload/Reverse Phase ProtectionAmbient temperature:-30…85℃weight:0.10kg
Electrical connections:Herssman joint (DIN43650)Power supply:15~30VDC

Standard range code table (unit bar)

(unit m, meter)(unit cm, cm)
range valueSelection coderange valueSelection code
0...0.5mM0.50…50cmCM50
0...1 mM10…100cmCM100
0…2mM20…200cmCM200
0…3mM30…300cmCM300
0…4mM40…400cmCM400
0...5 mM50…500cmCM500
0…~mM~0…~cmCM~
0…10mM100…1000cmCM1000
0…~mM~0…~cmCM~
0…50mM500…5000cmCM5000
(unit mm, mm)
range valueSelection code
0…500mmMM0.5
0…1000mmMM1000
0…2000mmMM2000
0…3000mmMM3000
0…4000mmMM4000
0…5000mmMM5000
0…~mmMM~
0…10000mmMM10000
0…~mmMM~
0…50000mmMM50000
Note: If the required liquid level range is not in the standard list, the measurement range value can be set according to customer requirements and displayed on site or transmitted remotely. For example, the required liquid level height range: 5.5 meters, the liquid level range code can be written as M5.5; 250 cm, the selection code is CM250; 800 mm, the selection code is MM800.

Selection table

LV61-Hydrostatic level transmitter (external)

range

Unit: m

Unit: cm cm

Unit: mm

type of medium

Water medium (nominal density 1.0X10?㎏/m?)

Oil or mixed medium (density needs to be noted when ordering)

Process connection interface thread (external thread)

M12*1.25

NPT1/4

NPT1/2

G1/4 *)

G1/2 *)

M20*1.5 (*)

Output signal type

4~20mA output (*)

0…10mA output

0~5VDC output

0~10VDC output

Electrical connections

Hessman joint (DIN43650)
The complete data of this selection table, please contact the sales staff or email to sales@kewill-auto.cn for complete samples.